TM 9-4910-387-14-1
REPAIR
WARNING
Kerosene is flammable. Injury or death to
personnel could result from misuse.
1 FLUID FILTER ELEMENT (1).
a.
Clean by immersing in kerosene (item 8, app C).
b.
Replace (TM 9-4910-387-24P) as required.
2 PLUG (2), BOLT ASSEMBLY (3), FLAT WASHER (4), BODY
ASSEMBLY (5), AND GASKET (6). Replace (TM 9-4910-
387-24P) as required.
REASSEMBLY
3 GASKET (4). Install in head (5).
4 BODY ASSEMBLY (2). Position under
head (5).
5 BOLT ASSEMBLY (6) WITH FLAT
WASHER (7). Tighten using a 1-in.
open end wrench.
1 PLUG (1). Install in body assembly (2).
2 FLUID FILTER ELEMENT (3). Place in body
assembly (2).
4-81