8 Remove both leads. Connect one multimeer lead to terminal D7
t
(8). Connect other lead in sequence to terminal A6 (32) and to
starter contact (33).
9 Remove both leads. Connect one multimeter lead to terminal C12
(34). Connect the other lead in sequence to holding relay coil
contact (35), START COUNT switch contact (36), and to holding
6-107