TM 9-4910-387-14-2
DISASSEMBLY OF RH CONTROL PANEL ASSEMBLY
NOTE
Before disconnecting and
removing wires, ensure that
all wires are identified and
tagged for reassembly.
2 SIX SCREWS (5 THRU 10) AND SIX
ATTACHED WIRES. Remove.
3 FUEL HEAT SWITCH (11) AND LUBE
HEAT SWITCH (12). Remove.
1 FOUR
SCREWS
(1),
FOUR
SWITCH PLATES (3 AND 4). Remove.
NOTE
Mark wires and both female
connector
plugs
for
reassembly. Plugs are part of
flush motor bases.
5 EIGHT SCREWS (14). Loosen and
remove eight attached wires.
6 TWO FEMALE CONNECTOR PLUGS
(15). Remove.
7 TWO FLUSH MOTOR BASES (16).
Remove.
4 FOUR SCREWS (13). Remove.
6-191