TM 9-4910-387-14-2
6-5. RH CONTROL EQUIPMENT ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)
DISASSEMBLY OF RH MOUNTING BOARD ASSEMBLY (cont)
5 TWO SCREWS (8 AND 9) AND TWO ATTACHED WIRES.
Remove from terminals D3 and D4.
6 FOUR SELENIUM RECTIFIER CONTACTS (10 THRU 13).
Desolder and remove four wires.
7 NUT (14) AND WASHER (15). Remove.
8 SELENIUM RECTIFIER (16). Remove.
9 LOCKWASHER (17), NUT (18), AND BOLT (19). Remove.
6-194