TM 9-4910-387-14-2
6-11. 24 VOLTS DC OUTLET ASSEMBLY-MAINTENANCE INSTRUCTIONS (cont)i
REASSEMBLY/INSTALLATION (cont)
3
WIRE (4).
a. Push through hole in instrument panel
assembly (5) and insert into receptacle
connector (6).
b. Solder to receptacle connector (6).
4
FITTING (3). Screw onto connector (1).
5
TWO WIRES (7 AND 8) WITH ONE TERMINAL LUG EACH. Install
on connector (1) and secure by loosely installing screw (9).
6
FITTING (3). Position on instrument panel assembly (5).
6-306