TM 9-4910-700-14 & P
/NOTE/
2-4. POINTS CHECK OPERATION. The test
set has built-in provision for testing
If the engine is warm, it may be nec-
the condition of distributor breaker
essary to disconnect the spark coil
points.
secondary wire to avoid starting engine
a. Follow steps a through d of
while cranking.
e. Note meter reading with engine
off but ignition switch on. If
f.
Set the dwell switch to the RES
position.
meter reads upscale, it is nec-
essary to advance engine by
Read the points condition on the
g.
cranking until meter does not
GO-NO-GO scale of the meter. A
deflect.
NO-GO condition is equivalent to
.2 volts of points voltage drop