4-62. HYDRAULIC LINES AND FITTINGS REPLACEMENT (Con't).
3.
Loosen understraps (5 and 11). Remove two tube assemblies (6 and 10) from multiple connector (7).
4.
Remove nut (8), Iockwasher (9), and multiple connector (7) from screw (18). Discard Iockwasher.
5.
Remove tube assembly (1 O) from connector (1 2). Remove tube assembly.
6.
Remove two tube assemblies (13) from connector (12) and each tee (15).
7.
Remove two fluid passage bolts (17), spacers (16), tees (15), and washers (14),
8.
Repeat steps 5 through 7 on opposite side.
b.
INSTALLATION
1.
Install tube assembly (13) in tee (15). Repeat for other tube assembly.
2.
Install two washers (14), tees (15), spacers (1 6), and fluid passage bolts (17).
3.
Connect each tube assembly (13) to connector (1 2).
A700258
4-152