TM 9-1330-200-11/OP 3833 1st Rev. Vol 2, CH-2 TM 1330-12/1A CH2
NOTE
Whenever storage space is noted, category C ammunition may be combined with category E.
Table 4-3. Category E
Minimum distance in feet between
Gross tons
Gross tons
Stacks
Stacks
FSU
per stack
per FSU
Unbarricaded
Barricaded
Unbarricaded
Categories
Less than 5...
50
75
60
300
900
5-10 max.
50
105
75
300
900
Table 4-4. Category F
Minimum distance in feet between
Gross tons
Stack barricaded
Gross tons
per stack
& unbarricaded
Der FSU
FSU unbarricaded FSU barricaded
Categories
The max. allowable
See note below-
20
200
75
1500
gross wt. per stack
30
230
90
1500
will be 20 tons.
40
265
99
1500
50
295
101
1500
60
330
120
1500
80
390
135
1500
100
455
150
1500
NOTE
The minimum distance between barricaded stacks will be 75 feet.
The minimum distance
between unbarricaded stacks will be 150 feet.
Table 4-5. Category G Class V
Minimum distance in feet between
Gross tons
per FSU
FSU unbarricaded
FSU barricaded
Categories
20
200
75
1500
30
230
90
1500
40
265
99
1500
60
299
101
1500
60
330
120
1500
80
390
135
1500
100
455
150
1500
NOTE
Under normal conditions, the Department of the Air Force will store and issue all class V
supplies; however, depot commanders should always be prepared to handle these supplies in
emergencies.
c. Allow at least 6-inch clearance beneath pile for
air circulation.
a. Use heavy, well supported dunnage to prevent
stack from sinking, and to keep bottom tier offground.
d. Dig suitable trenches to prevent water from
flowing under pile.
b. Use hardstand of gravel and sand rather than
excessive dunnage.