TM 9-2320-211-10-1
d.
Operation of Fuel-Burning Personnel Heater.
FRAME 1
Open fuel shutoff cock (1) by turning it to the left.
1.
Make sure that personnel heater EMERGENCY switch (2) is in the up position.
2.
3.
Pull AIR knob (3) to full out position.
Place HI-LO switch (4) in HI or LO position, depending on heat needed.
4.
Hold START-OFF-RUN switch (5) in START position until indicator light (6)
5.
comes on. START-OFF-RUN switch is spring loaded and must be held in
position.
As soon as the indicator light (6) comes on, move START-OFF-RUN switch (5)
6.
quickly to RUN position.
NOTE
Moving START-OFF-RUN switch (5) lever from START
position to RUN position too slowly will result in a heater
shutdown. Move switch lever quickly. Warm air should
be felt at the heat outlet within three minutes. If heater
fails to start within two minutes (indicator light (6) re-
mains off), move STARTOFFRUN switch to OFF posi
tion. Wait three minutes before trying to start heater
again.
GO TO FRAME 2