TM 9-2320-211-10-1
Set HI-LO switch (1) to LO position.
1.
Hold START-OFF-RUN switch (2) in START position until indicator light (3)
2.
comes on. Indicator light should come on within two minutes.
NOTE
START-OFF-RUN switch (2) is spring loaded and must
be held in position.
As soon as indicator light (3) comes on, quickly move START-OFF-RUN
3.
switch (2) to RUN position.
NOTE
Moving switch (2) lever from START to RUN too slowly
will result in a heater shutdown. Warm air should be
felt at the heat outlet within three minutes.
If heater fails to start within two minutes (indicator light (3) will remain
4.
off), move START-OFF-RUN switch (2) to OFF position. Wait until three
minutes before trying to start heater again.
Set HI-LO switch (1) to HI or LO depending on heat needed.
5.
NOTE
LO position of HI-LO switch (1) is suitable for standby
periods when heater will operate for a long period of
time.
GO TO FRAME 4
4-218