TM 9-2320-211-10
(Cont.)
TABLE
3-2.
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DUMP
BODY
HOIST
ASSEMBLY
37. Hoist assembly does not raise dump body.
Step 1. Check oil level in hydraulic oil reservoir.
If low, add oil (see LO 9-2320-211-12).
Step 2. Check for leak in hydraulic system
Inspect all connections for leaks, or othet causes.
Notify organizational maintenance.
38. Body raises to full dump, but does not power down.
Step 1. Check for leak in hydraulic system.
Inspect all connections for leaks, or othel causes.
Notify organizational maintenance.
39. Noisy hydraulic pump.
Step 1. Check oil level in hydraulic oil reservoir.
If low, add oil (see LO 9-2320-211 -12).
Step 2. Other causes.
Notify organizational maintenance
40. Fifth wheel not secure.
Step 1. Check mounting.
Tighten mounting screws.
Step 2. Other causes.
Notify organizational maintenance.
TA
067164