TABLE 3-2. TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
SLAVE RECEPTACLE
62. Slave cable connected but engine will not turn over.
Check for- poor- receptacle connection.
Step 1.
Make proper connection.
Step 2.
Check if slave receptacle battery cables are loose or discontlected.
Reconnect battery cables and tighten connections.
All other causes.
Step 3.
See organizational maintenance unit.
A-FRAME KIT
63. Winch inoperative.
Step 1. See if power takeoff is disengaged.
Engage power takeoff.
Step 2. See if shear pin is broken.
Replace shear pin.
64. A-frame inoperative or misalined.
Step 1. Check for loose cable clamps.
See organizational maintenance unit.
Step 2. See if A-flame is bent.
See organizational maintenance unit
DEEP WATER FORDING KIT
65. Fording control handle inoperative.
Step 1. See if wire is corroded.
Clean and lubricate wire (see LO 9-2320-211-12)