TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. ELECTRICAL SYSTEM (CONT)
e86.
15K SELF-RECOVERY WINCH (SRW) DOES NOT REEL IN (CONT).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
(h)
If 15K SRW still does not reel in, notify Unit Maintenance.
15K SELF-RECOVERY WINCH (SRW) DOES NOT PAY OUT.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
(h)
If 15K SRW still does not pay out, notify Unit Maintenance.
POWER TAKE-OFF (PTO) DOES NOT OPERATE.
Check circuit breaker (CB49) in PDP to see if it is tripped.
(a)
(b)
Position master power switch to off (para 2-27f).
(c)
If circuit breaker is tripped, push in to reset.
(d)
Position master power switch to on (para 2-27a or b).
(e)
Check circuit breaker to see if it tripped. If circuit breaker is tripped, notify Unit Maintenance.
(f)
Position master power switch to off (para 2-27f).
(g)
(h)
If PTO still does not operate, notify Unit Maintenance.
Change 1