DRAINCOCK - CONTINUED
ACTION
ITEM
REMARKS
LOCATION
REMOVAL
Draincock (2)
Using 9/16-inch open-end wrench,
1. Air reservoir (1)
unscrew and take off.
INSTALLATION
Wrap threads clockwise two
a.
2.
turns with teflon tape.
b.
Screw in, and tighten using 9/16-inch
open-end wrench.