TM 9-2330-247-14&P
PRESSURE TANK
Draining
This Task Covers:
Initial Setup:
Tools/Test Equipment:
Goggles, protective
ACTION
REMARKS
ITEM
LOCATION
DRAINING
Turn off.
Trailer air supply
Towing vehicle
1.
Unhook from towing vehicle air couplings (3).
Two air couplings (2)
Trailer A-frame (4)
2.
WARNING
Dry cleaning solvent, P-D-680, is toxic and flammable.
Always wear protective goggles and gloves, and use only in
a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT breathe vapors. DO NOT use near
open flame or excessive heat. The solvent's flash point is
100F-138F (38C-59C). If you become dizzy while
using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts eyes, immediately wash
your eyes and get medical aid.
a. Open and allow to completely drain.
Draincock (5)
Pressure tank (1)
3.
b. Close draincock (5).
Two air couplings (2)
Trailer A-frame (4)
4.
Turn on.
Trailer air supply
Towing vehicle
5.
TASK ENDS HERE
TA701046