TM9-2330-368-14 & P
Table 3-1. Operator Troubleshooting Table (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM (cont)
1. ALL LAMPS DO NOT LIGHT (cont).
Step 3.
Check connectors for dirty or corroded pins. Check for damaged pins.
a. If pins are dirty or corroded, clean the pins.
b. If pins are damaged, notify organizational maintenance.
If the above steps do not correct the malfunction, notify organizational maintenance.
c.
2. ONE OR MORE (BUT NOT ALL) LIGHTS WILL NOT LIGHT.
Step 1.
Check for burned out or defective lamps.
If lamps are burned out or defective, replace lamps (para. 3-5).
a.
b. If lamps are not burned out or defective, proceed to step 2.
Check for broken lead wires or loose connections.
Step 2.
a. If connections are loose, tighten connections.
b. If lead wires are broken, notify organizational maintenance.
c. If connections are not loose or broken, proceed to step 3.
Check light assembly for damage.
step 3.
If light assembly is damaged, notify organizational maintenance.
a.
b. If lens and light assembly are not damaged, proceed to step 4.
Check for dirty or corroded bulb socket.
step 4.
a. If socket is dirty, clean socket.
b. If the above steps do not correct the malfunction, notify organizational maintenance.
3-5