TM 9-2330-381-14
NOTE
The 50-ton hydraulic ram must be used to remove the ultra bushing because
additional pressure is required to break the ultra bushing free.
8.
Install 50-ton hydraulic ram (14) and adjuster (15) onto shaft (11). Ensure puller (9) is seated squarely in bore of
ultra bushing (12) and cannister (13) is seated squarely on ultra bushing housing (10). Hand tighten adjuster (15)
snugly against hydraulic ram (14).
WARNING
Hydraulic fluid can be absorbed through the skin. Wear long sleeves, gloves, and
goggles or face shield. If hydraulic fluid gets into the eyes, flush them immediately
with water and seek medical attention. If hydraulic fluid gets on skin, thoroughly
wash with soap and water. Wash hands thoroughly prior to eating or smoking.
9.
Connect hydraulic power source to hydraulic ram (14) and apply pressure until hydraulic ram (14) extends full
stroke. Recheck all tools for proper seating and alinement.
10.
Relieve hydraulic pressure and let return springs retract ram. Tighten adjuster (15) against hydraulic ram (14)
and apply hydraulic pressure.
5-35