TM 9-2330-384-14&P
4-70. JET LEVEL SENSOR REPLACEMENT (Con't)
(7) At jet level sensor (6), connect
tubing (4 and 11) to straight
adapters (1) and tighten nuts (5).
(8) Install straight adapters (22 and
26) and bleeder valve (27) to
emergency valve (12).
(9) Install tubing (25) between
straight adapter (26) and inlet of
strainer assembly (24). Install
tubing (23) between straight
adapter (22) and outlet of strain-
er assembly.
FOLLOW-ON TASKS:
4-221