TM 9-2330-384-14&P
4-71. STRAINER ASSEMBLY MAINTENANCE (Con't).
(5) Install screen (9) inside body
(10).
(6)
Install new gasket (8) and cap (6)
on body (10). Hold body with pipe
wrench and tighten cap securely.
b. REMOVAL
Place a pail under strainer as-
(1)
sembly to catch any draining fuel
when tubing (5 and 14) is discon-
nected.
Loosen nut (13) and disconnect
(2)
tubing (14) from straight adapter
(12). Loosen nut (4) and discon-
nect tubing (5) from straight
adapter (3). Dispose of any fuel
collected in pail in accordance
with local policy.
Hold body (10) with pipe wrench
(3)
and remove bushings (2 and 11)
from body. Remove body from
between mounting brackets (1).
Remove straight adapters (3 and 12) from bushings (2 and 11).
(4)
c. DISASSEMBLY
(1)
Remove cap (6) and gasket (8) from body (10). Remove plug (7) from cap.
(2) Remove screen (9) from body (10).
d. CLEANING AND INSPECTION
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Always wear protec-
tive goggles, face shield, and gloves, and use only in a well-ventilated
area. Avoid contact with skin, eyes, and clothes and DO NOT breathe
vapors. DO NOT use near open flame or excessive heat. The solvent's
flash point is 100F-138F (38C-59C). If you become dizzywhile using
cleaning solvent, immediately get fresh air and medical help. If solvent
contacts eyes, immediately wash your eyes with water and get medical
aid.
Compressed air used for drying purposes must not exceed 30 psi
(207 kPa). Wear protective clothing (goggles, face shield, and gloves)
and usecaution to avoid injury to personnel.
(1)
Use dry cleaning solvent to clean all removed components. Dry thoroughly with compressed
air.
4-223