TM 9-2330-384-14&P
4-76.
EMERGENCY VALVE AND VAPOR VENT CABLES AND TUBING MAINTENANCE
(Con't).
NOTE
If replacing only one length of tub-
ing (5), cable (11) should be
pulled out only just past grease fit-
ting (4).
(2)
From one end, pull cable (11) all
the way out.
(3)
Cut tubing (5) at several locations
along its length. Loosen nuts at
grease fitting (4).
CAUTION
Use caution when releasing tubing
(5) from under clips (2). Clips
should be lifted gently and only
enough to release tubing. Failure
to follow this caution will cause
clips to break off.
(4) Lift clips (2) and remove all
lengths of tubing (5). Remove
straight adapters at ends, as re-
quired. Remove grease fitting
(4).
(5) Inspect all grommets (8). Re-
place any damaged grommet.
(6)
Inspect grease fitting (4) and ca-
ble (11). Replace if damaged.
4-247