TM 9-2330-384-14&P
4-76. EMERGENCY VALVE AND VAPOR VENT CABLES AND TUBING MAINTENANCE
(Con't).
d. DISCONNECTION OF CABLE AND TUBING AT EMERGENCY VALVE
Loosen nut (17) and disconnect
(1)
cable (11) from adjusting bolt
(19).
From inside cabinet (7), pull ca-
(2)
ble (11) away from emergency
valve (6) by manually pulling on
cable that is second cable down,
attached to emergency valve
control lever (top lever). Loosen
nut (15) and disconnect tubing
(5) from straight adapter (16).
Remove nut (15) from straight
(3)
adapter (16). Remove straight
adapter from emergency valve
(6).
Pull tubing (5) and cable (11)
(4)
from emergency valve (6).
If damaged, remove two nuts
(5)
(18) and adjusting bolt (19) from
lever (14).
e. CONNECTION OF CABLE AND TUBING AT EMERGENCY VALVE
(1)
If removed, install adjusting bolt (19) to lever (14) and install two nuts (18).
(2)
Install straight adapter (16) to emergency valve (6). From inside cabinet (7)) pull cable (11)
away from straight adapter by manually pulling on cable that is second cable down, attached
to emergency valve control lever (top lever).
(3)
Connect tubing (5) to straight adapter (16) and tighten nut (15).
(4)
From inside cabinet (7), push cable (11) through tubing (5). Connect cable to adjusting bolt
(19) and tighten nut (17).
NOTE
Cable (11) length may be adjusted at both ends.
(5)
Pull on emergency valve control lever in cabinet (7) and check operation of cable (11). To
adjust length of cable at emergency valve (6), turn two nuts (18) at adjusting bolt (19). To
(6)
Lubricate cable (11) at grease fitting (4), as required (see Chapter 3, Section I).
4-250