TM 9-2330-386-14&P
ORGANIZATIONAL TROUBLESHOOTING TABLE - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - continued
2. ONE OR MORE LIGHTS WILL NOT LIGHT - continued.
Step 2.
C h e c k for burned lamp.
b. If lamp does not light, go to step 3.
Step 3.
Remove lamp and check lamp socket for dirt or corrosion.
a. Clean lamp socket, if dirty or corroded.
b. If lamp socket is clean, install lamp and go to step 4.
Step 4.
C h e c k for damaged light assembly.
b. If light assembly is not damaged, go to step 5.
Step 5.
Check plug and/or receptacle for dirty or corroded contacts.
a. Clean contacts, if dirty or corroded.
b. If contacts are not dirty or corroded, go to step 6.
Step 6.
Check for broken or shorted wire in cable or loose connection in
plug or receptacle.
a. Tighten, repair or replace as necessary.
b. If wiring and connections are not damaged, go to step 7.
S t e p 7.
R e m o v e nose plate (para. 4-23) and check for loose or broken ground
wires.
a. If ground wire is broken, repair or replace wire and install
nose plate.
b. If ground wire is loose, tighten connection and install nose
plate.
c. If ground wire is not broken and connection is tight, go to step
8.
Step 8. Check for open resistors.
b. Replace all open resistors and install nose plate (para. 4-26).
4-13