TM 9-2330-388-14
2-11.
Starting Engine Using Electric Starter
WARNING
Run engine on diesel fuel only. Use of
gasoline can cause an explosion, causing
death or injury to personnel and damage to
equipment.
CAUTION
Make sure water is flowing through the pump
within two minutes of starting dispensing
unit engine, to prevent damage to food grade
mechanical seal. Open discharge valve to
start water flow, and check by briefly
opening one of the faucets on a nearby
manifold. If water flows from open faucets,
water should be present at pump. If tank
water has been permitted to drop below the
Figure 2-6. Pressure Gage
emergency valve level an re-fill, open
discharge valve to assure a normal quantity
and flow of water before starting engine.
Figure 2-7. M1098 Water Piping
2-6