TM 9-2330-398-10
2-17.
ENGINE OPERATING INSTRUCTIONS (continued).
3.
After two minutes, set engine switch (11) on control panel (8) to RUN. Wait 15 seconds, then turn starter switch
(7) to START and crank for 15 seconds. Release starter switch (7).
NOTE
DO NOT disengage starter switch at first firing of engine. Continue with switch engaged for a
limited time (30 seconds maximum) to help engine run and gain speed.
4.
Wait one minute and turn starter switch (7) to START. Crank for one minute, or until running, then release starter
switch (7). Leave preheater switch (12) in ON position for about five minutes after engine starts.
5.
If engine still has not started, turn starter switch (7) to START and crank for one minute. Engine should be firing.
Release starter switch (7) when engine speed is increasing.
6.
Release preheater switch (12).
2-43