TM 9-2350-222-10-2
PREPARE FOR FIRING (LOAD SMOKE GRENADE DISCHARGERS) - Continued
WARNING
Follow ammunition handling procedures when handling and loading grenades.
Smoke grenades contain RP (red phosphorus). This is a fire hazard and is dangerous to all personnel outside tank.
Never place part of your body in front of the dischargers when removing or installing discharge covers.
2.
Remove covers (B) from left and right grenade dischargers (C).
3.
Stow covers (B) in fender box (D).
4.
Check that all barrels (E) of each discharger (C) are clear.
5.
Remove grenades (F) from stowage boxes (G).
WARNING
If any grenades have external cracks, dents, or
other deformities, DO NOT USE. Do not try to
disassemble grenades. Place damaged grenades
in storage/shipping containers and dispose of in
accordance with local regulations.
Change 9 2-388.2