TM 9-2350-222-10-3
MAINTAIN 7.62-MM MACHINE GUN (REPLACE BARREL
ASSEMBLY-M240) - Continued
3. Pull barrel assembly (J)
straight out.
To Install Replacement Barrel Assembly:
1. Hold replacement barrel
assembly (A) with barrel release
(H) up. Aline barrel assembly (A)
with receiver assembly (K)
and insert.
2.
Rotate barrel release (H) to right
and down.
3. Install M240 machine gun in
mount (page 2-336).
4. Return asbestos mittens to stowage. Return barrel assembly (J) to
organizational maintenance.
TA132980