TM 9-2350-277-10
OPERATE NBC KIT
THIS WORK PACKAGE COVERS:
INITIAL SETUP:
Maintenance Level
References
Operator
TM 3-4240-346-10
Personnel Required
Equipment Condition
Soldier
NBC Kit installed
TURN NBC KIT ON IN AMBULANCE WITH LITTER KIT
WARNING
Filters and masks of the NBC system will not protect you against carbon monoxide, ammonia,
acid, or solvent fumes. Be sure the carrier is properly ventilated. Do not let any filters of the
NBC system get wet. Water will destroy their ability to take the deadly chemical and biological
agents out of the air. Contaminated filters must be handled using adequate precautions and
must be disposed of by trained personnel. If it is very cold outside, there is danger of frostbitten
lungs from inhaling the cold air. Do not connect the hoses to your M42 mask canister until NBC
system has been operating at least 15 minutes with the heater turned on.
1.
Remove spring clip from air intake openings on air purifier.