TM 9-2350-277-10
TROUBLESHOOTING TABLE -- Continued
0089 00
INITIAL SETUP:
Maintenance Level
Operator
NBC KIT
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
INSUFFICIENT AIR FLOW
1.
Check to see if spring clip is down over air
Raise spring clip from air
AT ALL STATIONS.
intake openings on air purifier.
intake openings on air purifier
2.
Check to see if air hoses are kinked or
Straighten or replace air hoses
pinched.
3.
Check to see if it there are any loose hose
Tighten loose hose connections
connections.
2.
AIR FLOW TOO HIGH AT
1.
Check to see if air purifier is out of
If air purifier is out of adjustment,
ALL STATIONS.
adjustment.
notify unit maintenance.
3.
GAS PARTICULATE
Turn AIR PURIFIER SWITCH to
1.
Check to see if AIR PURIFIER SWITCH is
FILTER WILL NOT
ON.
in OFF position.
OPERATE WHEN SWITCH
IS IN ON POSITION.
2.
Check to see if ground wire is loose or
Notify unit maintenance of loose
missing.
or missing ground wire.
3.
Check to see if electrical cable assemblies
Notify unit maintenance.
are loose or missing.
Change 4