TM 9-2350-277-10
TROUBLESHOOTING TABLE -- Continued
0089 00
INITIAL SETUP:
Maintenance Level
Operator
BILGE PUMPS
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
BILGE PUMP DOES NOT
1.
Check to see if MASTER SWITCH is OFF.
Turn MASTER SWITCH to ON.
WORK WITH THE BILGE
PUMPS SWITCH ON.
2.
Check to see if bilge pump strainers or
Clean bilge pump strainers or
outlets are clogged.
3.
Check to see if bilge pump vents are blocked.
Clean bilge pump vents
get to the bilge pump to clean it
because of a load in the personnel
compartment, cycle the BILGE
PUMP switch ON and OFF
will usually start the pump.
Change 4