1 - STRIP CABLE INSULATION EQUAL TO DEPTH Of SOLDER
WELLS OF INSERTS.
2 - REMOVE GROMMET RETAINING NUT FROM PLUG ASSEMBLY
AND SLIDE BACK OVER CABLE.
3 - SLIDE GROMMET BACK FROM PLUG ASSEMBLY AND REMOVE
DAMAGED CABLE.
4 - PASS REPLACEMENT CABLE THROUGH GROMMET RETAINING
NUT AND GROMMET, INSERT INTO SOLDER WELLS Of
INSERTS. AND SOLDER.
5 - SLIDE GROMMET OVER INSERTS AND PRESS INTO PLUG
ASSEMBLY.
6 - THREAD GROMMET RETAINING NUT TO PLUG ASSEMBLY.
E - FEMALE TYPE PLUG ASSEMBLY (WITH HEXAGON NUT)
1 - STRIP CABLE INSULATION EQUAL TO DEPTH Of SOLDER
WELLS Of INSERTS.
2 - REMOVE GROMMET RETAINING NUT FROM PLUG ASSEMBLY
AND SLIDE BACK OVER CABLE.
3 - SLIDE GROMMET BACK FROM PLUG ASSEMBLY AND REMOVE
DAMAGED CABLE.
4 - PASS REPLACEMENT CABLE THROUGH GROMMET RETAINING
NUT AND GROMMET. INSERT INTO SOLDER WELLS OF
INSERTS, AND SOLDER.
5 - SLIDE GROMMET OVER INSERTS AND PRESS INTO PLUG
ASSEMBLY UNTIL SEATED.
6 - THREAD GROMMET RETAINING NUT TO PLUG ASSEMBLY.
NOTE. CONTACT SIZES 8, 4, AND 0 MAY BE REMOVED FROM
CONNECTOR TO SIMPLIFY REPAIR.
F - FEMALE - TYPE PLUG ASSEMBLY
AT19695
Figure 3-55. Replacement of cable female plugs.
3-72