HULL ELECTRICAL SYSTEM
1 - STRIP CABLE INSULATION EQUAL TO DEPTH Of SOLDER
WELLS OF INSERTS.
2 - REMOVE GROMMET RETAINING NUT FROM PLUG ASSEMBLY
AND SLIDE BACK OVER CABLE.
3 - SLIDE GROMMET BACK FROM PLUG ASSEMBLY AND REMOVE
DAMAGED CABLE.
4 - PASS REPLACEMENT CABLE THROUGH GROMMET RETAINING
NUT AND GROMMET. INSERT INTO SOLDER WELLS Of
5 - SLIDE GROMMET OVER INSERTS AND PRESS INTO PLUG
ASSEMBLY UNTIL SEATED.
6 - THREAD GROMMET RETAINING NUT TO PLUG ASSEMBLY.
G - MALE - TYPE PLUG ASSEMBLY (WITH SPANNER COUPLING NUT).
1 - STRIP CABLE INSULATION EQUAL TO DEPTH Of SOLDER
WELLS Of INSERTS.
2 - REMOVE GROMMET RETAINING NUT FROM PLUG ASSEMBLY
AND SLIDE BACK OVER CABLE.
3 - SLIDE GROMMET BACK FROM RECEPTACLE ASSEMBLY AND
REMOVE DAMAGED CABLE.
4 - PASS REPLACEMENT CABLE ENDS THROUGH GROMMET
RETAINING NUT AND GROMMET. INSERT. INTO SOLDER
5 - SLIDE GROMMET OVER INSERTS AND PRESS INTO
RECEPTACLE ASSEMBLY UNTIL SEATED.
6 - THREAD GROMMET RETAINING NUT TO RECEPTACLE
ASSEMBLY.
NOTE. CONTACT SIZES 8, 4, AND 0 MAY BE REMOVED FROM
CONNECTOR TO SIMPLIFY REPAIR.
H - FEMALE - TYPE RECEPTACLE ASSEMBLY
Figure 3-56. Replacement of cable male plugs and female receptacles.
3-73