TM 9-2590-506-13&P
3-5.
CONVERTER
ASSEMBLY
MAINTENANCE
(Continued).
b. Cleaning the Converter Assembly. Clean the
converter assembly as follows:
WARNING
Dry Cleaning Solvent (P-D-680), used
to
clean
parts,
is
potentially
dangerous
to
personnel
and
property.
Do not use near open
flame or excessive heat. Flash point
of dry cleaning solvent is 138 F
(59 C).
moistened in dry cleaning solvent (item 3,
the converter assembly (1).
(2) Using a nylon bristle brush (item 2,
reach areas and parts of the converter
assembly (1).
(3) Using a clean wiping rag (item 5,
(1) of any residual solvent or moisture.
c. Storing the Converter Assembly. Store the
converter assembly after completion of refueling
operations as follows:
(1) With the converter assembly (2) installed
in the bucket assembly (3) as instructed in
a dust free area protected from the
elements.
TA255011