TM 9-2590-506-13&P
Table 5-1. Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
LATCH COVER LEVER WILL NOT ENGAGE OR LOCK/UNLOCK.
a.
Actuate latch cover lever (1) from DISENGAGE to ENGAGE position while observing foot of latch (2).
(1) Foot shall point away from center of converter assembly with lever in ENGAGE position.
(2) Foot shall point to the left with lever (1) in DISENGAGE position.
b.
Actuate lever (1) to LOCK position and observe foot of latch (2).
(1) Foot shall raise up when in the LOCK position.
3.
DUST COVER ASSEMBLY CANNOT BE INSTALLED.
Check that dust cover assembly latches (1) do not interfere with other parts of converter assembly.
TA255013
5-3