4-28. Low Oil Pressure Shutdown Switch and "T" Connector.
b. Installation
c. Test
This task covers:
a. Removal
INITIAL SETUP
Equipment Condition
Tools
Materials/Parts
a. Removal. (figure 4-19)
(1) Tag and remove wiring from low oil pressure shutdown switch (1).
(2) Remove switch (1).
(3) Loosen fitting nut (2) and remove oil line (3).
(4) Remove "T" connector (4).
WARNING
Drycleaning solvent PD-680 used to clean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or
excessive heat. Flash point of solvent is 100F.-1 38F. (38C.-60C.).
(5) Clean switch (1) and "T" connector (4) with drycleaning solvent, and dry thoroughly.
(6) Inspect switch (1) and replace if damaged.
(7) Inspect "T" connector (4) and replace if damaged.
Installation. (figure 4-19)
b.
(1) Install "T" connector (4).
(2) Install oil line (3) and tighten fitting nut (2).
(3) Install switch (1).
(4) Connect wiring, as tagged, to switch (1).