NOTE
Removal or installation of wall structure panel assembly (standard, corner, evaporator,
or door frame panel assembly) may require loosening or removal of other connected
ceiling or wall panel assemblies. If door frame panel assembly is to be removed, first
remove walk-in door, vapor proof light fixture, and thermometer. Tape pads over
receptacles, switch, and pilot light to prevent damage.
REMOVAL
1. Remove sealing tape from external ceiling ends of wall structure panel assembly to be replaced
.
2. Unlock camlocks at ceiling and floor ends of wall structure panel assembly requiring replacement.
3. Unlock camlocks connecting the panel assembly to adjacent wall structure panel assemblies.
4. Remove wall panel assembly. If needed, loosen or remove connected ceiling panel assembly and/or wall panel
assembly to allow easy removal or installation.
INSTALLATION
1. Position replacement wall panel assembly. If removed, position any connecting wall panel assembly. Lock
together adjacent wall panel assemblies.
2. With wall assemblies locked together, lock floor ends of wall panel assemblies to the floor panel assembly(s).
3-33