TM 9-4110-246-14
TO 40R7-5-10-1
3. If loosened or removed, reposition ceiling panel assembly and lock ceiling ends of wall panel assembly(s) to
ceiling.
4. Apply new sealing tape over applicable ceiling and wall panel assembly joints.
3-30. REMOVE/INSTALL FEMALE RECEPTACLE.
TOOLS: Screwdriver, Flat Tip
Pocket Knife
WARNING
The lighting circuit operates on 125V ac. Shut off power supply at its source before
beginning this procedure or disconnect power cable from source. Failure to heed this
warning may result in death or injury.
REMOVAL
1. Slide boot (1) off female receptacle (4).
2. Loosen retaining clamp screws (2) with screwdriver.
3. Separate halves (3 and 4) of female receptacle.
4. Tag and disconnect wires (5) to female receptacle.
INSTALLATION
1. Slide cap (3) of female receptacle onto the power cord.
2. Connect wires (5) to terminals of female receptacle.
3. Snap halves (3 and 4) of female receptacle together.
4. Using screwdriver, tighten screws (2) to secure power supply cord to clamp.
5. Slide boot (1) over female receptacle.
3-34