TM 9-4110-246-14
TO 40R7-5-10-1
3-34. REMOVE/INSTALL MALE RECEPTACLE, CAP AND CHAIN.
TOOLS: Screwdriver, Flat Tip
REMOVAL
WARNING
The lighting circuit operates on 125V ac. Disconnect male power receptacle before beginning
this procedure. Failure to heed this warning may result in death or injury.
1. Loosen and remove screws (1) with screwdriver.
2. Gently pull male receptacle (2) and cap and chain (3) away from door frame to gain access to using panel
assembly.
3. Tag and disconnect wires (4) at rear of receptacle.
INSTALLATION
1. Connect wires (4) to receptacle (2) terminals as tagged and remove wire tags.
2. Position receptacle (2) and cap and chain (3) onto door frame panel assembly. Secure with screws (1) using
screwdriver.
3. Reconnect power to power receptacle.
3-40