TM 9-4110-254-14
Table 4-1. Unit Preventive Maintenance Checks and Services for Model F5000RE - Continued
Location
Item
Interval
Item to
Procedure
Not Fully Mission
Check/
Capable If:
Service
10
Semi-
Lamp
Inspect the lamp assembly for cracked or missing
Wire leads are loose.
Annually
Assembly
cap, loose base, and loose wire leads Tighten cap
if loose If damaged, wire leads are loose, or base
is loose, test, tighten base or wire leads, or replace
11
Semi-
Hourmeter
Inspect the hourmeter for cracked or missing lens
Wire leads are loose.
Annually
or any other damage and loose or missing
mounting hardware and wire leads If damaged or
wire leads or mounting hardware is loose, tighten,
NOTE
Operating the toggle switch can
cause the refrigeration unit to start
or shut down.
12
Semi-
Toggle Switch
Toggle switch will not
Inspect the toggle switch for any damage and
Annually
stay in START/RUN
loose or missing mounting hardware or wire leads
position.
Wire leads
Inspect for smooth operation to START/RUN and
are loose.
OFF. If damaged, or wire leads or mounting
hardware is loose, or operation is stiff or binding,
4-18