TM9-4110-254-14
(11) If no failure was indicated, close control panel (3). Install two new lock washers (2) and bolts (1).
b.
Repair.
(1)
Remove defective thermal overload heater (6).
(2)
Install thermal overload heater (6).
c.
Removal.
(1)
Be sure power has been disconnected at the source and remove two bolts (1) and lock washers (2). Open
control panel (3). Discard lock washers.
Figure 4-20. Motor Starter
NOTE
Steps 2 through 4 apply only to new motor starter. A new motor starter is configured
with jumpers connected for operation at 115 Vac and must be reconnected for use with
208/230 Vac.
(2) Tag and disconnect wire leads (8).
(3) Remove screw (9), lock washer (10), and flat washer (11). Discard lock washer.
(4) Remove two each bolts (12), lock washers (13), and flat washers (14), and motor starter (5). Discard lock
washers.
4-55