TM9-4110-254-14
4-25.
MOTOR STARTER K1 TESTING, REPAIR, AND REPLACEMENT. -Continued
d.
Installation.
(1)
Install three new thermal overload heaters (6) onto new motor starter (5).
(2)
Remove two red wire lead jumpers between terminals L2 to 96 and A1 to 3 Discard jumpers.
(3)
Move red wire lead jumper from between terminals A2 to 95 and place between terminals A1 to 95.
(4)
Set overload adjustment (FLA) dial to A position and (RESET) adjustment dial to M position.
(5)
Install motor starter (5), two flat washers (14), new lock washers (13), and bolts (12).
(6)
Install flat washer (11), new lock washer (10), and screw (9).
(7)
Using tags and wiring diagram (fig 1-4), install wire leads (8). Remove tags.
(8)
Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control box cover door.
Connect power and put unit back into service.
4-56