TM 9-4110-254-14
4-39. PULLEY REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions
General Safety Instructions.
disconnected
WARNING
High voltage and exposed rotating parts are
used in the refrigeration unit Personal injury
can result if power is connected.
a.
Removal Loosen set screw (1) and remove pulley (2) from AC motor (3) shaft being careful not to lose
key (4).
b.
Installation Install key (4) then aline pulley (2) with key and slide onto AC motor (3) shaft Tighten set
screw (1)
Figure 4-34. Pulley
NOTE
FOLLOW-ON MAINTENANCE
Connect power and put unit back into service
4-87