TM 9-4110-254-14
4-40. GROUND STRAP (MOTOR) REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions
Lock Washers (1)
WARNING
Equipment Conditions'
High voltage and exposed rotating parts are
used in the refrigeration unit Personal jury
disconnected.
can result if power is connected.
a. Removal. Remove bolt (1), lock washer (2), bolt (3), and ground strap (4) Discard lock washer.
b. Installation Install ground strap (4), new lock washer (2), bolt (1) and bolt (3).
Figure 4-35. Ground Strap (Motor)
NOTE
FOLLOW-ON MAINTENANCE.
Connect power and put unit back into service
4-88