TM 9-4110-254-14
4-50. GREASE FITTING EXTENSION REPLACEMENT.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Materials/Parts:
General Safety Instructions.
Self Locking Nuts (2)
WARNING
Equipment Conditions
High voltage and exposed rotating parts are
used in the refrigeration unit Personal jury
disconnected.
can result if power is connected.
a. Removal.
NOTE
Grease fitting is not supplied with grease fitting extension
(1)
Remove grease fitting (1).
(2)
Remove two self locking nuts (2), bolts (3), flat washers (4), clamps (5) and one spacer (6) Discard self
locking nuts.
(3)
Remove grease fitting extension (7) and two grommets (8).
Figure 4-45. Grease Fitting Extension
4-106