TM 9-4110-255-14
NOTE
The following procedures apply to all three control relays K1, K2 and K3. Quantities given are for
each relay.
(2) Tag and disconnect wire leads (4).
(3) Remove bolt (6), lock washer (7), flat washer (8), and control relay (5). Discard lock washer.
c. Installation.
NOTE
The following procedures apply to all three control relays K1, K2 and K3. Quantities given are for
each relay.
(1) Install control relay (5), flat washer (8), new lock was er (7), and bolt (6).
h
(3) Using tags and wiring diagram (fig. 1-4), install wire leads (4). Remove tags.
(4) Close control panel (3). Install two new lock washers (2) and bolts (1).
Figure 4-18. Control Relays
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control box cover door.
Connect battery (para 4-35) and put unit back into service.
4-63