TM 9-4110-255-14
4-25. TIME DELAY RELAYS TD1 AND TD2 TESTING AND REPLACEMENT. - Continued
c. Installation.
NOTE
The following procedures apply to both TD1 and TD2. Quantities given are for each relay.
Terminal hardware is supplied with time delay relay.
(1) Secure time delay relay (7) or (8) to mounting plate (13) using adhesive t pe. Install screw (14) through
a
mounting plate into time delay relay.
(2) Install time delay relay (7) or (8), using two flat washers (11), new lock washers (10), and bolts (9).
(4) Using tags and wiring diagram (fig. 1-4), install wire leads (6), nuts (4) and screws (5). Remove tags.
(5) Close control panel (3). Install two new lock washers (2) and bolts (1).
NOTE
FOLLOW-ON MAINTENANCE:
Unlatch and close control box cover door.
Connect battery (para 4-35) and put unit back into service.
4-66