TM 9-4110-255-14
This task covers:
a. Testing
b. Removal
c. Installation
INITIAL SETUP
Materials/Parts:
Equipment Conditions:
Lock Washers (2)
Refrigeration unit shut down (para 2-7) and battery
Lock Washers (2)
Control box cover door raised and latched.
Marker tags (4)
(1) Be sure battery has been disconnected then remove two bolts (1) and lock washers (2). Open control
panel (3). Discard lock washers.
Figure 4-26. Control Transformer T1
(2) Tag and disconnect wire leads (4).
2 and 5 to 8. Continuity should be indicated. If no continuity was indicated, replace control transformer.
(4) Check continuity between either terminals 1 to 5, or 1 to 8. No continuity should be indicated. If continuity
was indicated, replace control transformer.
4-82