TM 9-4110-255-14
5-5.
BATTERY SHIELD REPAIR
This task covers:
Repair
INITIAL SETUP
Materials/Parts:
Equipment Conditions:
Self Locking Nuts (4)
Refrigeration unit shut down (para 2-7) and battery
Gasket
Right side door open.
Gasket (2)
Repair.
(1)
Remove four self locking nuts (1), flat washers (2), and battery clamp (3). Discard self locking nuts.
(2)
Remove two L-bolts (4), and shield (5).
(3)
Remove as much old gasket material (6) or (7) as possible by pulling or scraping it away from the
shield (5).
(4)
Soften and remove old adhesive and gasket (6) or (7) residue, using acetone or methl-ethyl ketone
y
(MEK) and a stiff brush.
(5)
Be sure that the attaching surface of the battery shield (5) is clean and free of paint and old adhesive
material.
(6)
Coat the mating surfaces of the shield (5) and gasket (6) or (7) with adhesive. Let both surfaces air dry
until adhesive is tacky, but will not stick to fingers.
(7)
Starting with an end, carefully press gasket (6) or (7) onto the shield (5). Press firmly overall to ensure
complete contact.
(8)
Install two L-bolts (4) and slide shield (5) into position.
(9)
Install clamp (3), four flat washers (2), and new self locking nuts (1).
5-8