5-11. PURGING THE REFRIGERANT SYSTEM . - Continued
(8)
Check to be sure that no oil is being discharged during purge.
(9)
Perform any brazing/debrazing operations necessary (para 5-12).
(11) Disconnect the charge hose from nitrogen regulator.
5-12. BRAZING/DEBRAZING PROCEDURE .
This task covers:
a. Debrazing
b. Cleaning
c. Brazing
INITIAL SETUP
Materials/Parts:
General Safety Instructions:
Brazing Alloy
WARNING
Brazing alloys and flux contain materials
Rags
which are hazardous to health. Avoid
breathing vapors or fumes from brazing
Abrasive Cloth
operations. Perform operations only in well
ventilated areas. Wash hands with soap and
Equipment Conditions:
Wear gloves and protective goggles or face
shield to protect against burs.
a.
Debraze.
(1)
Protect wiring harnesses and other components with appropriate heat shields.
NOTE
It may be easier to access a component by cutting or debrazing the copper lines in accessible
areas and removing part of the interconnecting tubing with the component.
(2)
If debrazing a joint on a valve, disassemble the valve to the extent possible and wrap all but the joint
with wet rag to act as a heat sink.