TM 9-4110-255-14
5-40. COMPRESSOR B1 TESTING, SERVICE, REPAIR, AND REPLACEMENT .
This task covers:
a. Testing
b. Service
c. Repair
d. Removal
e. Installation
INITIAL SETUP
Materials/Parts:
Materials/Parts:
Self Locking Nuts (4)
Marker tags (4)
Lock Washers (4)
Anti-Seize Tape
Discharge Valve Stops (2)
Compressor Lubricating Oil
Discharge Valves (2)
Insulation Tape
Suction Valves (2)
Equipment Conditions:
Suction Valve Position Spring
Front door open.
Right side door open.
Gasket General Safety Instructions:
Gasket
WARNING
Gasket
Compressor lubricating oil used in this
refrigeration system is caustic. Wear gloves
Gasket
and a face protector or safety glasses in any
situation where skin or eye contact is possible.
Gasket
If oil does contact skin, wash with soap and
water.
Gasket
a. Testing.
WARNING
Dangerous pressure can remain trapped in compressor cylinder head. Removal of cylinder head
bolts prior to relieving pressure can result in personal injury.
(3) Loosen but do not remove six screws (1), and two studs (2). Ifcylinder head (3) is not loose, tap with
lightweight hammer to loosen.
5-71