TM 9-4110-256-14
Table 2-1. Preventive Maintenance Checks and Services for Model F1000RE
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
21
Weekly
Guards
Inspect the guards for any debris or foreign
Debris or foreign material
material obstructing the openings. Remove any
obstructs the guard
debris or foreign material from the guard
openings.
openings. If debris cannot be removed, notify
unit maintenance to remove it.
22
Weekly
Gasket
Inspect for loose or missing gasket and for splits
or tears. If damaged or loose, notify unit
maintenance to tighten or replace it as
necessary.
23
Weekly
a.
Debris or foreign material
Frame
and loose or missing hardware. If
obstructing the condensate
cracked, notify direct support
drain opening.
maintenance for repair. If hardware is
loose or missing, notify unit maintenance
to tighten or replace is as necessary.
b.
Inspect the frame for any chipped or
missing paint and evidence of corrosion.
If paint is damaged or frame shows
evidence of corrosion, notify unit
maintenance to paint it.
c.
condensate drain plastic tubing for any
debris or foreign material obstructing it.
Remove any debris or foreign material
from the condensate drain tubing. If
tubing cannot be cleaned, notify unit
maintenance to clean it.
2-13